SAF’IR™ EVOLUTION
Evidential breathalyzer

The SAF’IR™ EVOLUTION is an evidential breathalyzer that guarantees high precision results using infrared technology. This technology is specifically designed to identify ethanol and its quantity in the breath sample.

The absorption value is aligned with the alcohol concentration level and is used to calculate the Breath Alcohol Concentration (BrAC) level, providing accurate test results. With a user-friendly design, long battery life and an in-vehicle adapter, the SAF’IR™ EVOLUTION is the breathalyzer of choice for law enforcement officials worldwide.

Each SAF’IR™ EVOLUTION evidential breathalyzer kit comes equipped with a NiMH battery, AC charger, DC charger, 25 mouthpieces, a printer, 2 roles of printer paper, AC charger for printer, instruction manual, quick guide and a durable plastic carry case.

A methodological logbook can be included in the kit depending on the geographic region.


  • 1 year warranty offered to ensure that your device is taken care of.
  • High precision infrared technology provides you with accurate test results every time.
  • DOT certified breathalyzer.
  • Can also scan the environment for the presence of alcohol without active user participation.
  • Conveniently stores your previous test results.
  • Built in rechargeable battery will allow you to perform up to 300 breath test without recharging.
  • Displays a calibration reminder for your convenience.
  • You will only need to calibrate once in a year.
Specifications
Handset size 85mm x 255mm x 46mm
Handset weight 600 grams
Display Graphic LCD
Battery Built-in rechargeable NiMH battery
Memory Over 3,200 time-stamped events with Bluetooth printing
Calibration Dry gas / wet gas
Measuring Principle Infrared spectrometry ethanol molecule-selective 9.46 µm-wavelength
Measuring Cycle Automatic with monitoring and diagnosis of good operation
Measurement Unit mg/L of alcohol in exhaled air, µg/L air, g/L blood BAC, %BAC
Measuring Range 0 to 2,00 mg/L (0 to 450 BAC)
Measurement Display Function of unit chosen, accuracy maximum 1 µg/L
Measuring Frequency Ready to blow in less than 30 seconds
Data Transfer PC via USB port and ACS software
Features Bluetooth printing and GPS applications
Certification OIML R 126 1998 – edition international recommendation
Operating temperature -5°C to +40°C
Battery life > 20 hours